Description
Specifications
Quick installation and reliable fixation – ideally suited for effective thermal insulation reinforcement.
LIN insulation anchor 10 × 180 mm with a short expansion zone and fiberglass reinforced polyamide nail is designed for simple and quick mechanical installation of insulation materials, especially when the substrate material is not very dense or when it is necessary to reduce the drilling depth. This anchor provides high durability while maintaining a straightforward installation process.
Advantages:
- Short expansion zone – reduces the required drilling depth, allowing installation in thinner structures
- Fiberglass reinforced polyamide nail – lightweight yet resistant to pull-out and breakage
- 60 mm pressure plate – uniform load distribution on the insulation material
- Non-metallic construction – prevents thermal bridges, ideally suited for ETICS systems
- ETA certification – complies with European technical requirements
Technical Information:
- Drill diameter: 10 mm
- Drill depth: ≥ 60 mm
- Effective anchoring depth: ≥ 50 mm
- Pressure plate diameter: 60 mm
- Anchor material: polypropylene (PP)
- Nail material: fiberglass reinforced polyamide
- Certification: ETA (European Technical Assessment)
ACCEPTED SUBSTRATE | DENSITY [kg/dm³] | MINIMUM PRESSURE [N/mm²] | APPLICABLE STANDARD | Characteristic Resistance NRk [kN] |
---|---|---|---|---|
Concrete C12/15 (application category A) | EN 206 | 0.55 | ||
Concrete C16/20 to C50/60 (application category A) | EN 206 | 0.80 | ||
Ceramic solid bricks MZ (application category B) | ≥2.0 | ≥20.0 | EN 771-1 | 1.00 |
Calcium silicate bricks KS (application category B) | ≥2.0 | ≥20.0 | EN 771-2 | 0.40 |
Vertically perforated ceramic bricks Porotherm 25 P+D (category C) | ≥0.8 | ≥15.0 | EN 771-1 | 0.10 |
Hollow calcium silicate blocks KSL (application category C) | ≥1.6 | ≥15.0 | EN 771-2 | 0.10 |
Lightweight concrete blocks LAC (application category D) | ≥0.88 | ≥5.0 | EN 771-3 | 0.20 |
Partial safety factor for anchor resistance ɣM (1) | 2.0 | 2.0 | 2.0 | 2.0 |
Installation:
![]() | ![]() | ![]() | ![]() |
1) Drill the wall | 2) Insert the anchor into the hole | 3) Secure the anchor by inserting the plugs | 4) Properly installed insulation connector |
|
Suitable for:
- Securing mineral wool, foam, and other insulation materials
- ETICS (external thermal insulation composite systems)
- Construction work with limited drilling depth
- New construction and renovation projects